ASSALUB automatic lubricator type FEM

Assa lubricator FEM

Type FEM has 1-12 outlets and is larger and more powerfulthan the FLM and is used for lubrication systems with grease requirements up to approx. 1.4 cm³ per minute per outlet, with continuous back pressure up to 250 bar. When used with progressive distributors the FEM may also be used to serve significantly more bearings than the 12 outlets provided.

pdf

 

number of outlets : 1 - 12
back pressure, continuous : 250 bar
back pressure intermittent : 450 bar
feed / pump stroke : 0,05 - 0,25 cm3
pump strokes / minute 50Hz : 5,6 - 2,8 - 1,4 - 0,7
pump strokes / minute 60Hz : 6,6 - 3,3 - 1,7 - 0,8
surface finish

:

Polyester powder paint 100 µm
Colour RAL 9006

available motors:
electrical data : acc. to IEC 34-1
manufacturer : Brook Crompton
Isolation class : F
protection class : IP55
available voltages : 3 x 220-240 / 380-420 V 50 Hz voltage code 1
3 x 250-275 / 440-480 V 60 Hz voltage code 1
3 x 500 V 50 Hz voltage code 2
3 x 400 / 690 V 50 Hz voltage code 3
3 x 575 V 60 Hz voltage code 4
other* voltage code 9
available power ratings : 0.18 kW / 1370 rpm 50 Hz
0.21 kW / 1680 rpm 60 Hz
0.25 kW / 2810 rpm 50 Hz
0.28 kW / 3370 rpm 60 Hz



* Other manufacturers’ motors with other voltages including single-phase operation with stand-by heating, Nema or CSA approval etc. are available on special request.

 

Dimensions:

afmetingen bovenaanzichtafmetingen zijaanzicht

 

Location of outlets:

posities pompelementen

Weight incl. motor, excl. resrevoir : 31 kg

 

Standard reservoirs:

volume (liter) weight (kg) height (mm) part code
8 7,2 280 8S
16 9,6 530 16S
46 16 830 46S

standaard reservoirs

Reservoirs with high- and low alarm:

volume (liter) weight (kg) height (mm) part code
5 7,4 280 5HLA
13 9,8 530 13HLA
40 16 830 40HLA

reservoirs met hoog- en laagalarm

Reservoirs with high- and low alarm, marine:

volume (liter) weight (kg) height (mm) part code
5 8 350 5HLAM

HLAM

 

 

Electrical data for reservoir level transducer:

1, 2 alarm contact closes at alarm level (NO)
3, 4 lower contact closes at low level (NO)
5, 6 upper contact closes at high level (NO)
maximum power rate : 50 VA
maximum voltage rating : 250 V
maximum current rating : 3 A
protection class : IP67
connection box : IP54

elektrische aansluitingen

pdf